DC/DC Converter
•
•
•
•
•
TEC 2WI Series, 2 Watt
Compact SIP-8 package
I/O-isolation voltage 1‘600 VDC
Ultra-wide 4:1 input voltage range
Fully regulated outputs
Operating temperature range –40°C to
+ 93°C
•
•
•
Continuous short circuit protection
•
3-year product warranty
Remote On/Off
Designed to meet IEC/EN/UL 62368-1
(not certified)
TEC 2WI is a new series with the design purpose to improve the prevalent 2
Watt SIP-8 DC/DC converters in terms of cost, efficiency and performance. The
latest technology and components enable an increase in efficiency by more
than 20%. With the reduction of thermal loss, the operating temperature range
can be expanded from -40°C to +93°C. The converters are fully regulated over
0 - 100% load (no minimum load is required). The models are available with ultra-wide input ranges of 4.5-18, 9-36 and 18-75 VDC. The functional I/O-isolation system is designed to meet IEC/EN/UL 62368-1 (not certified) with a test
voltage (60 s) of 1600 VDC.
Models
Order Code
Input Voltage
Range
TEC 2-1210WI
TEC 2-1211WI
TEC 2-1219WI
TEC 2-1212WI
TEC 2-1213WI
TEC 2-1215WI
TEC 2-1221WI
TEC 2-1222WI
TEC 2-1223WI
TEC 2-2410WI
TEC 2-2411WI
TEC 2-2419WI
TEC 2-2412WI
TEC 2-2413WI
TEC 2-2415WI
TEC 2-2421WI
TEC 2-2422WI
TEC 2-2423WI
TEC 2-4810WI
TEC 2-4811WI
TEC 2-4819WI
TEC 2-4812WI
TEC 2-4813WI
TEC 2-4815WI
TEC 2-4821WI
TEC 2-4822WI
TEC 2-4823WI
www.tracopower.com
4.5 - 18 VDC
(12 VDC nom.)
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
500 mA
400 mA
222 mA
167 mA
134 mA
83 mA
200 mA
83 mA
67 mA
500 mA
400 mA
222 mA
167 mA
134 mA
83 mA
200 mA
83 mA
67 mA
500 mA
400 mA
222 mA
167 mA
134 mA
83 mA
200 mA
83 mA
67 mA
November 14, 2023
Vnom
Efficiency
Imax
–5 VDC
–12 VDC
–15 VDC
200 mA
83 mA
67 mA
–5 VDC
–12 VDC
–15 VDC
200 mA
83 mA
67 mA
–5 VDC
–12 VDC
–15 VDC
200 mA
83 mA
67 mA
typ.
75 %
80 %
81 %
81 %
82 %
82 %
80 %
82 %
81 %
76 %
80 %
80 %
82 %
82 %
82 %
79 %
82 %
80 %
74 %
79 %
81 %
82 %
81 %
81 %
79 %
81 %
81 %
Page 1 / 4
TEC 2WI Series, 2 Watt
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
35 mA typ.
20 mA typ.
10 mA typ.
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
2 VDC min. / 3 VDC typ. / 4 VDC max.
6 VDC min. / 7 VDC typ. / 8 VDC max.
13 VDC min. / 15 VDC typ. / 17 VDC max.
1'000 mA (slow blow)
500 mA (slow blow)
315 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Capacitor
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
Capacitive Load
- Cross Regulation
(25% / 100% asym. load)
- 20 MHz Bandwidth
- single output
- dual output
±1% max.
0.2% max.
0.2% max.
1% max.
1% max. (Output 1)
1% max. (Output 2)
dual output models: 5% max.
single output models:
dual output models:
single output models:
dual output models:
3.3 Vout models:
5 Vout models:
9 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
5 / -5 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Time
75 mVp-p typ.
3'300 µF max.
1'680 µF max.
1'000 µF max.
820 µF max.
680 µF max.
220 µF max.
1'000 / 1'000 µF max.
470 / 470 µF max.
330 / 330 µF max.
Not required
±0.02 %/K max.
10 ms typ. / 20 ms max.
Continuous, Automatic recovery
130 - 230% of Iout max.
170% typ. of Iout max.
500 µs typ. (25% Load Step)
Safety Specifications
Standards
Designed for IEC/EN/UL 62368-1 (not certified)
- IT / Multimedia Equipment
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
External filter proposal: www.tracopower.com/overview/tec2wi
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 14, 2023
Page 2 / 4
TEC 2WI Series, 2 Watt
EMS Immunity
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
- PF Magnetic Field
Air: EN 61000-4-2, ±8 kV, perf. criteria A
Contact: EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
Ext. input component: KY 220 μF / 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous: EN 61000-4-8, 100 A/m, perf. criteria A
1 s: EN 61000-4-8, 1000 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
95% max. (non condensing)
–40°C to +93°C
+105°C max.
–55°C to +125°C
Power Derating
4.8 %/K above 84°C
See application note: www.tracopower.com/overview/tec2wi
Cooling System
Natural convection (20 LFM)
Remote Control
On: open circuit
- Current Controlled Remote
Off: 2 to 4 mA current (internal 1 kΩ resistor)
(passive = on)
Refers to 'Remote' and '-Vin' Pin
External circuit proposal: www.tracopower.com/info/current-remote.pdf
2.5 mA typ.
- Off Idle Input Current
Regulator Topology
RCC Converter
Switching Frequency
100 kHz min. (PFM)
Insulation System
Functional Insulation
Isolation Test Voltage
1'600 VDC
- Input to Output, 60 s
Isolation Resistance
1'000 MΩ min.
- Input to Output, 500 VDC
Isolation Capacitance
50 pF max.
- Input to Output, 100 kHz, 1 V
Reliability
- Calculated MTBF
6'621'000 h (MIL-HDBK-217F, ground benign)
Washing Process
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Environment
MIL-STD-810F
- Vibration
MIL-STD-810F
- Mechanical Shock
MIL-STD-810F
- Thermal Shock
Housing Material
Non-conductive Plastic (UL 94 V-0 rated)
Potting Material
Silicone (UL 94 V-0 rated)
Pin Material
Copper
Pin Foundation Plating
Nickel (1 - 2 µm)
Pin Surface Plating
Tin (3 - 5 µm), matte
Housing Type
Plastic Case
Mounting Type
PCB Mount
Connection Type
THD (Through-Hole Device)
Footprint Type
SIP8
Soldering Profile
Lead-Free Wave Soldering
260°C / 10 s max.
Weight
4.5 g
www.tracopower.com/info/reach-declaration.pdf
Environmental Compliance - REACH Declaration
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
- RoHS Declaration
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
79f309d9-36d3-4626-af05-f90a5ee70fbe
- SCIP Reference Number
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 14, 2023
Page 3 / 4
TEC 2WI Series, 2 Watt
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tec2wi
Outline Dimensions
4.1
2 x 2.54
5.08
3 x 2.54
2.0
(2 x 0.1)
(0.2)
(3 x 0.1)
(0.08)
(0.44)
(0.16)
0.5
(0.02)
11.2
Pinout
21.8
Pin
Single
Dual
1
–Vin (GND)
–Vin (GND)
2
+Vin (Vcc)
+Vin (Vcc)
3
Remote On/Off
Remote On/Off
5
NC
NC
6
+Vout
+Vout
7
–Vout
Common
8
NC
–Vout
(0.86)
6
0.5
(0.02)
7
8
9.1
5
(0.36)
3
(0.01)
2
0.25
1
3.2
Bottom View
(0.13)
NC: Not connected
Dimensions in mm (inch)
Tolerances: ±0.5 (±0.02)
Pin pitch tolerances ±0.25 (±0.01)
Pin dimension tolerance ±0.1 (0.004)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. November 14, 2023
Page 4 / 4
很抱歉,暂时无法提供与“TEC 2-1215WI”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+87.33044
- 3+85.12271
- 5+83.82098
- 国内价格
- 1+817.50704
- 2+799.54317
- 4+782.37075